Skip to content

Errors

All errors share one envelope, which always includes telemetry:

{ "job_id": "…", "backend": "…", "status": "REJECTED",
  "error": { "type": "…", "message": "…", "details": { … } },
  "telemetry": { "engine_invoked": false, … } }

status is REJECTED for 4xx and FAILED for 5xx. Error types travel unchanged from worker to client.

HTTP Type Raised by When Key details
400 QASMSyntaxError orchestrator / worker malformed source line, col
400 QASMSemanticError orchestrator / worker undeclared names, bad arity, out-of-range index, unknown include line
400 UnsupportedFeatureError orchestrator / worker outside the supported OpenQASM 3 subset; return_statevector with mid-circuit measurement line
400 InvalidRequestError both bad option values or combinations, payload too large, schema violations errors, limits
401 AuthenticationError orchestrator missing or invalid API key (only when keys are configured) —
404 UnknownBackendError orchestrator backend not registered available
404 JobNotFoundError orchestrator unknown, expired or foreign async job job_id
409 JobStateError orchestrator cancelling a job that is not QUEUED status
422 TopologicalCompilationError worker uncoupled qubit pair, or a disabled qubit qubits, line, statement, neighbors, adjacency_entry, reason
422 NativeGateError worker strict mode: non-native gate or off-grid angle gate, primitive, native_gates, allowed
422 CompilationError worker no native lowering exists gate
422 ResourceLimitError both more qubits than the device; over the simulation cap; memory guard; no connected region for routing required_bytes, available_bytes, max_feasible_qubits, max_sim_qubits
422 CalibrationProvenanceError worker strict provenance mode and unpublished values used unpublished_parameters
500 QPUTwinError both internal error (should not happen; please report) —
502 BackendProtocolError orchestrator the worker returned a non-QPUTwin payload —
503 BackendUnavailableError orchestrator no reachable replica (connection refused or DNS) replicas
503 QueueFullError orchestrator QPUTWIN_ASYNC_MAX_QUEUED reached queued, max_queued
504 BackendTimeoutError orchestrator the worker did not answer within QPUTWIN_REQUEST_TIMEOUT_S —
507 (QPUTwinError) worker MemoryError despite the guard (defensive backstop) —

Examples

These are real responses from the running stack. The memory-guard example reports the memory that was actually free on the host at the time.

{"type": "TopologicalCompilationError",
 "message": "'cx q[0],q[2];' (line 7) requires a two-qubit interaction between physical qubits 0 and 2, which are not coupled on rigetti_ankaa_3 (grid 7x12, nearest-neighbour only; no routing)",
 "details": {"device": "rigetti_ankaa_3", "gate": "cx", "primitive": "CX", "qubits": [0, 2], "line": 7,
             "statement": "cx q[0],q[2];", "neighbors": {"0": [1, 12], "2": [1, 3, 14]}, "adjacency_entry": 0}}
{"type": "ResourceLimitError",
 "message": "a dense 36-qubit complex128 statevector run needs ~3.0 TiB but only 5.2 GiB is available to this worker; at most 26 simulated qubits fit (use complex64 precision, raise the container memory limit, or touch fewer qubits)",
 "details": {"simulated_qubits": 36, "required_bytes": 3298534883328, "available_bytes": 5617725440,
             "max_feasible_qubits": 26, "precision": "complex128", "device": "ionq_forte", "engine": "statevector"}}
{"type": "CalibrationProvenanceError",
 "details": {"unpublished_parameters": ["gates.cz.duration_ns", "gates.prx.duration_ns", "readout.fidelity"],
             "device": "iqm_emerald"}}

Handling errors in clients

  • 4xx: fix the request; retrying will not help.
  • 409, 404 on poll: check the job state or id.
  • 503 QueueFullError: back off and retry later.
  • 503 BackendUnavailableError, 504: transient; retry with backoff. Asynchronous jobs are retried automatically by the queue after an instance crash, but never after a worker timeout, because the worker may still be executing the job.